Fundamental of Generator Protection

What You Will Learn!

  • Generators Protection
  • Working of Gas Turbine
  • Simplified Single Line Diagram of Generator Turbine Power Station
  • Performance of Synchronous Machines
  • Power Plant Layout and Grounding Techniques
  • Classification of Generator Tripping
  • Class A Protection, Class B Protection, Class C Protection
  • Types of Fault and location of faults, Types of Generator Protection
  • Generator Differential Protection
  • Restricted Earth Fault Protection
  • Negative Sequence or Unbalance Protection
  • Protection against inadvertent Energization
  • Over Current Protection
  • Voltage Controlled Over Current Protection
  • Inter Turn Short Circuit Protection
  • Over and Under Voltage Protection
  • Under and Over Frequency Protection
  • Loss of Excitation and Mho Characteristics
  • Vector Shift Relay
  • Reverse Power Relay
  • Impedance Protection of Generator
  • 2nd and 3rd Zones of Impedance Protection
  • Stator Earth Fault Protection
  • Over Excitation or Over Flux Protection
  • Rotor Earth Fault Protection
  • Out of Step Protection
  • ROCOF Protection
  • Bearing Insulation Protection
  • Generator Low forward power protection
  • Thermal Over Load Protection Stator and Rotor
  • Frequency Adaptivity and Generator Startup protection
  • Protection against Rotor Distortion
  • Generator Vibration Protection
  • Directional Neutral Overcurrent
  • Circuit Breaker Failure Protection
  • Load Encroachment
  • VT Fuse Fail VT MCB Fail Function
  • Tripping Philosophy and sequential Tripping
  • Single Line Diagram and Trip Matrix in brief

Description


Course Highlights

Generators are most important part of power system, they are called as heart of power system. Therefore protection of generators is ultimate requirement, turbine-generators are also very costly part of the power system. Course consist of 42 lectures & total duration of 5 hours and 36 mins.

This course was made as a reference guide for generator protection. Protection relays that are described in this course are applicable to one or more generator protection schemes.

There are a number of protection relay types and those are used for protection against a wide variety of conditions. These protection relays protect the generator or prime mover from damage. Also they are used for protection of the external power system or the processes it supplies. The basic principles that are described in this course apply equally to individual relays and to multifunction numeric relays.

This online course is intended for engineers with a desire to understand the fundamentals of generator protection. Upon successful completion engineers will be able to address key generator protection concepts, terms and characteristics.

Learning Objectives

This course is intended to provide you with the following specific knowledge and skills:

1. Introduction to Power System and Power Plants

2. Simplified Single Line Diagram of Generator Turbine Power Station

3. Working of Gas Turbine overview

4. Performance of Synchronous Machines

5. Power Plant Layout and Grounding Techniques

6. Classification of Generator Tripping

7. Class A Protection

8. Class B Protection

9. Class C Protection

10. Types of Fault and location of faults

11. Types of Generator Protection

12. Generator Differential Protection

13. Restricted Earth Fault Protection

14. Negative Sequence or Unbalance Protection

15. Protection against inadvertent Energization

16. Over Current Protection

17. Voltage Controlled Over Current Protection

18. Inter Turn Short Circuit Protection

19. Over and Under Voltage Protection

20. Under and Over Frequency Protection

21. Loss of Excitation and Mho Characteristics

22. Vector Shift Relay

23. Reverse Power Relay

24. Impedance Protection of Generator

25. 2nd and 3rd Zones of Impedance Protection

26. Stator Earth Fault Protection

27. Over Excitation or Over Flux Protection

28. Rotor Earth Fault Protection

29. Out of Step Protection

30. ROCOF Protection

31. Bearing Insulation Protection

32. Generator Low forward power protection

33. Thermal Over Load Protection Stator and Rotor

34. Frequency Adaptivity and Generator Startup protection

35. Protection against Rotor Distortion

36. Generator Vibration Protection

37. Directional Neutral Overcurrent

38. Circuit Breaker Failure Protection

39. Load Encroachment

40. VT Fuse Fail VT MCB Fail Function

41. Tripping Philosophy and sequential Tripping

42. Single Line Diagram and Trip Matrix in brief